Precision & Analytical Balance
Four readabilities, from a 0.01 g bench scale to a 0.1 mg analytical balance with a glass draft shield.
Test kits save 10%. Free shipping over $300.
48 products
Four readabilities, from a 0.01 g bench scale to a 0.1 mg analytical balance with a glass draft shield.
Spin down prepared analytical samples, pellet particulates, and clarify solutions before chromatographic analysis.
Variable-speed vortex with touch and continuous modes for dissolving and mixing samples.
Digital dry bath holding 37 °C ± 1 °C: equipment for research-use incubation within a qualified LAL workflow.
Digital 40 kHz bath for degassing mobile phase and dissolving stubborn samples.
Benchtop pH meter with automatic temperature compensation and 3-point calibration.
Prepared research-use equipment for growth observation under qualified laboratory conditions: 20–25 °C for tryptic soy broth, 30–35 °C for thioglycollate.
Benchtop ionizing blower that neutralises static on vials, spatulas and weighing boats.
300 Å, 5 µm C18 designed for reversed-phase separation of peptide research samples. Three dimensions for HPLC and LC-MS.
Matched C18 guard cartridges that protect the analytical column from particulates and strongly retained junk.
9 mm screw-thread amber glass vials with bonded PTFE/silicone septum caps.
13 mm hydrophilic PVDF filters with low peptide binding, for clarifying samples before injection.
All-glass vacuum filtration set for filtering and degassing mobile phase through 47 mm membranes.
47 mm nylon membranes for aqueous and organic mobile phases.
Aluminium-backed silica plates with a 254 nm fluorescent indicator, for qualitative comparison of research samples and reference materials. Cut to any size.
Dual-wavelength lamp for visualising spots on F254 TLC plates.
Glass developing tank with a ground-glass lid, for 20 x 20 cm plates cut to size.
α-Cyano-4-hydroxycinnamic acid, recrystallised. Supports sample preparation for mass analysis of peptides under about 5 kDa.
MALDI matrix supporting sample preparation for mass analysis of larger peptides and small proteins above about 5 kDa.
Low-background water for LC-MS mobile phases, spotting solutions and blanks.
Pipette tips packed with C18 resin that support sample preparation for mass analysis by desalting and concentrating peptide samples.
Research-use gel-clot LAL kit with a stated sensitivity of 0.125 EU/mL.
Certified endotoxin-free, racked tips for LAL work, in 200 µL and 1,000 µL.
Endotoxin-free water for reconstituting lysate and CSE and for dilutions.
Baked, endotoxin-free borosilicate tubes for gel-clot reactions and dilutions.
Prepared research-use soybean-casein digest medium for growth observation under qualified laboratory conditions.
Prepared research-use medium for growth observation of anaerobic and aerobic organisms.
Single-use PES filter units for research sample clarification and laboratory membrane-filtration studies.
BCA reagents for method-dependent estimation of peptide or protein concentration at 562 nm.
Bovine serum albumin standard in sealed ampules for building BCA calibration curves.
Fully autoclavable single-channel pipette with a lockable volume and soft-touch ejector.
Racked, sterile filter tips with a low-retention surface so peptide solutions don't cling.
Small anti-static polystyrene boats that release fine powders cleanly.
Polycarbonate desiccator with a stopcock, for bringing vials to room temperature dry and storing standards.
USB data logger with an external probe and alarm, for recording freezer and fridge temperatures.
Two micropipettes covering 2–200 µL, with a matched box of filter tips.
BCA reagents and BSA standard for relative or estimated concentration measurements. Response depends on sequence, matrix, and calibration; BSA may not provide an absolute peptide-content value.
Plates, development chamber and UV lamp for qualitative TLC comparison and detection of unexpected spots. Not an identity confirmation or purity measurement.
A pH meter and ultrasonic bath for preparing buffers, dissolving samples and degassing mobile phase.
Vials, syringe filters, mobile-phase membranes and HPLC-grade water: the consumables for a first run of peptide research samples. Solvents and acid modifiers are not supplied — order those from a chemical distributor.
Prepared research-use equipment and media for growth observation under qualified laboratory conditions. Not a stand-alone sterility certification or release test.
Dissolve, mix, measure and filter: the bench kit for getting samples ready to inject.
CHCA matrix, C18 desalting tips and LC-MS grade water supporting sample preparation for mass analysis.
A 0.001 g balance with an anti-static ionizer for steady weights on lyophilized powder.
Equipment and supplies for research-use incubation within a qualified LAL workflow. These products do not by themselves constitute a validated endotoxin method or establish product safety or release eligibility.
Lysate, LAL reagent water, depyrogenated tubes and endotoxin-free tips: the consumables for a gel-clot run. Control standard endotoxin is supplied by your lysate vendor and is not sold here.